MasterCharger Battery Charger-Analyzer for Aircraft
PN: MasterCharger
Price: Please request a quote below.
Large battery systems (10A-Hr to 100A-Hr)
Details:
- True Constant Current
- Adjustable, 0 To 50a On Charge
- And 0 To 60a On Discharge
- Dual Rate Charging
- Automatic Main To Topping
- Services Nickel-cadmium And Lead-acid Batteries
- Services One Or Two Batteries
- Charge Or Discharge
- 0 To 50 Cells Total, 80v Max
- Singe Cell Charging
- 100% Solid State
- Digital Meters
- Voltmeter And Ammeter Input For External Leads For Individual Cell Measurements
- Safe Operation
- Reverse Polarity, Short Circuit And Open Circuit Protected Battery Over Temperature
- Three Modes Of Operation
- Constant Current
- Constant Voltage
- Peak Voltage
Specifications:
- CURRENT
- Charge: constant current, adjustable, 0 to 50A (in increments of 0.1A)
- Discharge: constant current, adjustable, 0 to 60A (in increments of 0.1A)
- VOLTAGE:
- Charge: 0 to 80.0V
- Discharge: 3 to 30V (22 cells) at full current, and at reduced currents (30A) for up to 60V.
- MODES:
- Constant Current Charge
- Constant Voltage Charge
- Peak Voltage Charge
- Capacity Test
- Full Discharge
- CELLS/VOLTAGE CONTROL:
- # of cells (Nickel-Cadmium) for Constant Current Charge and for Capacity Test.
- Nominal Battery Voltage for Constant Voltage and
- Peak Voltage Charge (using the Cell Selector).
- METERS:
- Voltage: 3-1/2 digit LED digital panel meter, 0 to 19.99V and 0 to 199.9V scales.
- System accuracy: ±0.25%, ±1 digit
- Current: 3-1/2 digit LED digital panel meter, 0 to 199.9A scale.
- System accuracy: ±1%, ±1 digit
- VISUAL STATUS INDICATORS:
- Output ON/Cycle End, Voltage Fault, Capacity Failure.
- AUDIBLE STATUS INDICATORS:
- Beeper, End of Cycle or Fault condition.
- CONTROLS:
- Function Selector Keypad, Time Selectors, Voltmeter Source and Scale Selector Switch.
- Voltage and Current Selectors.
- Charge Mode Selector Switch.
- TIMER:
- Crystal Controlled with HH:MM, MM:SS and Test programming speeds. Battery backed-up for power line interruption protection..
- PROTECTION:
- Reverse polarity, short circuit, open circuit, over/under current, internal overheat, power failure and battery over temperature.
- LINE VOLTAGE:
- 208, 220-240VAC, ±10%, 50-60 Hz
- AMBIENT:
- +5o C to +35o C
- INTERFACING:
- Connections to the BTAS16 for Status Monitoring and Control.
- WARRANTY:
- One year parts and labor.