MasterCharger Battery Charger-Analyzer (10A-HR to 100A-HR)

$
0
0

mastercharger-battery-analyzer-charger

MasterCharger Battery Charger-Analyzer for Aircraft
PN: MasterCharger
Price: Please request a quote below.
Large battery systems (10A-Hr to 100A-Hr)

Details:

  • True Constant Current
    • Adjustable, 0 To 50a On Charge
    • And 0 To 60a On Discharge
  • Dual Rate Charging
    • Automatic Main To Topping
  • Services Nickel-cadmium And Lead-acid Batteries
  • Services One Or Two Batteries
    • Charge Or Discharge
    • 0 To 50 Cells Total, 80v Max
  • Singe Cell Charging
  • 100% Solid State
  • Digital Meters
    • Voltmeter And Ammeter Input For External Leads For Individual Cell Measurements
  • Safe Operation
    • Reverse Polarity, Short Circuit And Open Circuit Protected Battery Over Temperature
  • Three Modes Of Operation
    • Constant Current
    • Constant Voltage
    • Peak Voltage

Specifications:

  • CURRENT
    • Charge: constant current, adjustable, 0 to 50A (in increments of 0.1A)
    • Discharge: constant current, adjustable, 0 to 60A (in increments of 0.1A)
  • VOLTAGE:
    • Charge: 0 to 80.0V
    • Discharge: 3 to 30V (22 cells) at full current, and at reduced currents (30A) for up to 60V.
  • MODES:
    • Constant Current Charge
    • Constant Voltage Charge
    • Peak Voltage Charge
    • Capacity Test
    • Full Discharge
  • CELLS/VOLTAGE CONTROL:
    • # of cells (Nickel-Cadmium) for Constant Current Charge and for Capacity Test.
    • Nominal Battery Voltage for Constant Voltage and
    • Peak Voltage Charge (using the Cell Selector).
  • METERS:
    • Voltage: 3-1/2 digit LED digital panel meter, 0 to  19.99V and 0 to 199.9V scales.
    • System accuracy: ±0.25%, ±1 digit
    • Current: 3-1/2 digit LED digital panel meter, 0 to 199.9A scale.
    • System accuracy: ±1%, ±1 digit
  • VISUAL STATUS INDICATORS:
    • Output ON/Cycle End, Voltage Fault, Capacity Failure.
  • AUDIBLE STATUS INDICATORS:
    • Beeper, End of Cycle or Fault condition.
  • CONTROLS:
    • Function Selector Keypad, Time Selectors, Voltmeter Source and Scale Selector Switch.
    • Voltage and Current Selectors.
    • Charge Mode Selector Switch.
  • TIMER:
    • Crystal Controlled with HH:MM, MM:SS and Test programming speeds. Battery backed-up for power line interruption protection..
  • PROTECTION:
    • Reverse polarity, short circuit, open circuit, over/under current, internal overheat, power failure and battery over temperature.
  • LINE VOLTAGE:
    • 208, 220-240VAC, ±10%, 50-60 Hz
  • AMBIENT:
    • +5o C to +35o C
  • INTERFACING:
    • Connections to the BTAS16 for Status Monitoring and Control.
  • WARRANTY:
    • One year parts and labor.